Hello,
I have two fixed bins for a product having capacity of maximum weight 25 KG each. When I am putting away the qty of 30 KG, I am expecting to create two warehouse task. one for 25 KG to full-fill maximum capacity of first bin and remaining 5 Kg in other bin. But system is throwing an error, System is checking full put-away qty qty 30 KG and checking against capacity of each bin 25 KG. I am getting an error. "Maximum number of fixed bins (2) reached in storage type 0050." I am expecting to fill the first fix bin to its maximum capacity and then put away remaining qty to other bin. I have done following setting. Please guide me whether I need to do any other setting?
1. I have maintained storage bin max weight 25 KG
2. Weight =1 KG in product master in unit of measure tab.
3. My product is not managed in HU type. Hence no HU type is maintained.
Thanks,
Milind